Problem description
The sealing connection is stressed by an internal pressure. If the internal pressure drops below approx. 20 N/mm² load on the gasket, the sealed connection opens. A next start-up is only possible after changing the gasket or the sealing connection is tightened after reaching the maximum pressure under pressure and temperature.
Requirements for a re-equipment
- no restriction on the number of start-up and shut-down processes
- Lifetime >3-6 years
- external checked documentation
Solutions
- Calculation of the optimal / permissible installation screw forces
- Reduction of the gasket width
- The gasket is placed blow-out-safed and safe against overloading
- Use of additional spring columns
- Checking and, if necessary, revision of the sealing surfaces
Design limits
- Design pressure: up to approx. 200 bar
- Design temperature: up to approx. 400°C
- Gasket diameter: oval up to an external dimension of approx. 700 mm
- Screw size: up to approx. M48 / 2 inch