High pressure steam boiler

High pressure steam boiler

Problem description  


The sealing connection is stressed by an internal pressure. If the internal pressure drops below approx. 20 N/mm² load on the gasket, the sealed connection opens. A next start-up is only possible after changing the gasket or the sealing connection is tightened after reaching the maximum pressure under pressure and temperature.


Requirements for a re-equipment

  • no restriction on the number of start-up and shut-down processes
  • Lifetime >3-6 years
  • external checked documentation

Solutions

  • Calculation of the optimal / permissible installation screw forces
  • Reduction of the gasket width
  • The gasket is placed blow-out-safed and safe against overloading
  • Use of additional spring columns
  • Checking and, if necessary, revision of the sealing surfaces

Design limits

  • Design pressure: up to approx. 200 bar
  • Design temperature: up to approx. 400°C
  • Gasket diameter: oval up to an external dimension of approx. 700 mm
  • Screw size: up to approx. M48 / 2 inch

Share by: