Retrofit of Valves
Tank farm valves can be retrofitted at the spindle (stem) seal on-site and while the tank is filled. For this purpose, spring-loaded packing sets are used, providing low friction for easy operability of the valve stems and designed for an operating pressure of at least 16 bar.
A complete overhaul of the valves must be carried out in the workshop with the valve removed, since in this case the cover gasket is also replaced.
All materials used are certified according to TA-Luft. Valves with the described spindle sealing system have now been certified in accordance with EN 15848.